EasyManua.ls Logo

INVT EC160

INVT EC160
227 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User manual of EC160 elevator intelligent integrated machine Fault code
214
58 109
Constant
speed over
voltage
braking unit
4. ACC/DEC
curve is too swift
braking resistor
5.Adjust S curve
59 110
Under-
voltage fault
1.Sudden power
off
2.Too low input
voltage
3.Abnormal drive
control board
1.Check the
external power
supply and
whether the power
is off when the
motor is running
2.Check the
contacting layer of
the input power
supply
3.Contact with the
manufacturer
Stop
immediately;
fault reset
automatically
60 111
Motor
overload
1.Wrong
parameters
setting
2.Abnormal
braking circuit
3.Too heavy load
1.Adjust the
parameters
2.Check the
braking circuit
Stop
immediately;
fault reset
automatically
61 112
System
overload
1. Abnormal
braking circuit
2.Too large load
3.Check the
encoder
feedback signal
4.Check the
parameters of
the master
5.Check the
power cable of
the master
1.Check the
braking circuit and
braking devices
2.Reduce the load
3.Check the
feedback signal of
the encoder and
the original angle
of the encoder
4.Check the
parameter setting
of the name plate
of the master
Stop
immediately;
fault reset
automatically

Table of Contents