User manual of EC160 elevator intelligent integrated machine Fault code
215
5.Check the
power cable of the
master
62 113
Phase loss
in input side
1.Asymmetrical
input power
2.Abnormal drive
control board
1.Set through the
parameters
2.Check the 3
phase power
supply in input
side and the
power voltage
3.Contact with the
manufacturer
Stop
immediately;
fault reset
automatically
63 114
Phase loss
in output
side
1.Loose
connection of the
output of the
main circuit
2.Damage to the
master
1.Check the
contactor in input
side
2.Solve the
master fault
Stop
immediately;
fault reset
automatically
64 115
Overheat of
the
rectification
module
1.Sudden
overcurrent
2.Output
grounding short
circuit
3.Air duct block
or damage
4.Environment
temperature is
too high
5.Control board
or plug-in loose
6.Abnormal main
board or damage
to the sensor
1.Refer to the
overcurrent
measurement
2.Reconfigure
3.Dredge the air
duct or change the
fan
4.Reduce the
temperature
5.Contact with the
manufacturer
Stop
immediately;
fault reset
automatically
65 116
Overheat of
the
converting
module

Table of Contents