User manual of EC160 elevator intelligent integrated machine Fault code
216
66 118
485
communica-
tion fault
Check the
parameters setting
Fault tips
67 119
Current
detection
fault
1.Bad
connection of the
control board
2.Auxiliary power
damage
3.Hall device
damage
4.Amplifying
circuit abnormal
5.No enabling of
the drive module
1.Check the cable
of the main board
and the drive
board
2.Replace the
main board or
main control board
3.Check the main
board
Stop
immediately;
fault reset
automatically
68 120
Autotuning
fault of the
motor
1.Wrong setting
of the autotuning
static current of
the master
2.Wrong
parameters
setting
3.The capacity
does not match
that of the drive
board
4.The running
contactor does
not close
1.Adjust the
autotuning static
identification
current
2.Set the rated
parameters
according to the
name plate of the
motor
3.Check the motor
connection
4.Change the
drive board
Stop
immediately;
fault reset
automatically
69 121
Encoder
offline
1.Encoder
damage or offline
2.Too short time
for offline
detection
1.Check the
encoder and the
connection
2.Check the
braking
3.Check the
Stop
immediately;
fault reset
automatically