Function
code
Name Detailed instruction of parameters
Default
value
P0.14 Reserved 0~65535 0
P0.15 Reserved 0~65535 0
P1 Group Speed curve adjustment
P1.00 Increasing acceleration 1 0.001~1.000m/s
3
0.350
P1.01 Increasing acceleration 2 0.001~10.000m/s
3
0.350
P1.02 Acceleration speed 0.001~1.000m/s
2
0.700
P1.03 Reducing deceleration 1 0.001~10.000m/s
3
0.350
P1.04 Reducing deceleration 2 0.001~10.000m/s
3
0.350
P1.05 Deceleration speed 0.001~1.000m/s
2
0.700
P1.06 Door area 0~1000mm 200
P1.07 Zero-speed threshold 0~0.050m/s 0.000
P1.08
Pre-opening speed
threshold
0~0.200m/s 0.050
P1.09 Inspection speed 0~0.630m/s 0.200
P1.10
Peristaltic landing
speed
0~0.200m/s 0.030
P1.11 UPS running speed 0~1.000m/s 0.100
P1.12 Landing speed 0~1.000m/s 0.200
P1.13 Autotuning speed 0~1.000m/s 0.100
P1.14 Landing precision 0~100mm 50
P1.15 Reserved 0~65535 0
P1.16
High-speed current
loop proportional
coefficient
0~65535 0
P1.17
High-speed current
loop integral time
0~65535 0
P2 Group Motor parameters
P2.00 Motor type selection
0: Asynchronous master
1: Synchronous master
1
P2.01
Rated power of the
motor
0.1~150.0kW
Depend on
model