EasyManua.ls Logo

INVT EC160

INVT EC160
227 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User manual of EC160 elevator intelligent integrated machine Debugging tools
55
Function
code
Name Detailed instruction of parameters
Default
value
P5.04
Overload pre-warning
threshold
20.0%~150.0% 130.0
P5.05
Overload pre-warning
selection
0: Corresponds to the rated current of the
motor, detecting all the time
1: Corresponds to the rated current of the
motor, detecting when constant speed
2: Corresponds to the rated current of the
machine, detecting all the time
3: Corresponds to the rated current of the
machine, detecting when constant speed
0
P5.06
Overload pre-warning
delay time
0.0~30.0s 5.0
P5.07
Automatic fault reset
times
0~3 3
P5.08 Fault reset interval 0.1~100.0s 5.0
P5.09
Threshold of over
speed deviation
0.1%~50.0% 20.0
P5.10
Detection time of over
speed deviation
0.000~10.000s 0.500
P5.11
Braking threshold
voltage
320.0~750.0V 700.0
P5.12
Ramp cancelling
current delay
0~65535ms 0
P5.13 Reserved 0~65535 0
P6 Group Communication setting (reserved)
P7 Group Drive information
P7.00 Year setting 2000~2099 2010
P7.01 Month/date setting 01.01~12.31 01.01
P7.02 Hour/minute setting 00.00~23.59 12.00
P7.03
Rectification module
temperature
-20.0~100.0°C Read only

Table of Contents

Related product manuals