User manual of EC160 elevator intelligent integrated machine Debugging tools
55
Function
code
Name Detailed instruction of parameters
Default
value
P5.04
Overload pre-warning
threshold
20.0%~150.0% 130.0
P5.05
Overload pre-warning
selection
0: Corresponds to the rated current of the
motor, detecting all the time
1: Corresponds to the rated current of the
motor, detecting when constant speed
2: Corresponds to the rated current of the
machine, detecting all the time
3: Corresponds to the rated current of the
machine, detecting when constant speed
0
P5.06
Overload pre-warning
delay time
0.0~30.0s 5.0
P5.07
Automatic fault reset
times
0~3 3
P5.08 Fault reset interval 0.1~100.0s 5.0
P5.09
Threshold of over
speed deviation
0.1%~50.0% 20.0
P5.10
Detection time of over
speed deviation
0.000~10.000s 0.500
P5.11
Braking threshold
voltage
320.0~750.0V 700.0
P5.12
Ramp cancelling
current delay
0~65535ms 0
P5.13 Reserved 0~65535 0
P6 Group Communication setting (reserved)
P7 Group Drive information
P7.00 Year setting 2000~2099 2010
P7.01 Month/date setting 01.01~12.31 01.01
P7.02 Hour/minute setting 00.00~23.59 12.00
P7.03
Rectification module
temperature
-20.0~100.0°C Read only