User manual of EC160 elevator intelligent integrated machine Debugging tools
54
Function
code
Name Detailed instruction of parameters
Default
value
P4.22 Rated load 0~10000kg 1000
P4.23
Weighing input
selection
0: Digital input
1: Analog input of car
2: Analog input of engine room
0
P4.24
Weighing
compensation input
channel
0: No compensation
1: Communication input
2: Terminal input
0
P4.25 Pre-torque bias 0.0~100.0% 45.0
P4.26
Bias and gain at the
braking side
0.000~5.000 2.000
P4.27
Bias and gain at the
drive side
0.000~5.000 2.000
P4.28
Analog filter of car
weighing
0.00~0.50s 0.10
P4.29
Analog filter of engine
room weighing
0.00~0.50s 0.10
P4.30
Smooth filter time of the
curve
0~20ms 6
P4.31
Monitoring output
selection
0~65535 0
P5 Group Elevator protection parameters
P5.00
Input phase loss
protection
0: Prohibit
1: Enabling
2: Only enabling in running
1
P5.01
Output phase loss
protection
0: Prohibit
1: Enabling
1
P5.02
Motor overload
protection
0: Disabled
1: Normal motor
2: Variable frequency motor
2
P5.03
Motor overload
protection current
20.0%~120.0% 100.0

Table of Contents