User manual of EC160 elevator intelligent integrated machine Debugging tools
59
Function
code
Name Detailed instruction of parameters
Default
value
L0.01 Up bias floor 0~64 0
L0.02 Down bias floor 0~64 0
L0.03 Parallel home floor 0~64 0
T0 Group Time setting
T0.00 Open delay 0~500.0s 3.0
T0.01 Reserved 0~500.0s 45.0
T0.02
Return to the home
floor delay
0~5000.0s 120.0
T0.03
Free energy-saving
delay
0~5000.0s 60.0
T0.04 Brake opening delay 0~5.000s 0.200
T0.05 Brake closing delay 0~5.000s 0.400
T0.06
Starting shake
prevention delay
0~5.000s 0.300
T0.07 Direction cancel delay 0~5.000s 0.200
T0.08
Inspection stopping
delay
0~5.000s 0.300
T0.09 Fire running delay 0~5.000s 0.000
T0.10 Arrival gong delay 0~5.000s 0.000
T0.11
Thermal protection
reset delay
0~5000s 600
T0.12 Pre-opening delay 0~5.000s 0
T0.13
Peristaltic landing
overtime
0~5.000s 0
T0.14 Speed reference delay 0~5.000s 0.500
T0.15
Braking voltage shifting
delay
0~5.000s 0
T0.16
Opening delay keeping
time
0~500.0s 30.0
T0.17
Entire running
protection time
0~100.0s 45.0