User manual of EC160 elevator intelligent integrated machine Debugging tools
60
Function
code
Name Detailed instruction of parameters
Default
value
T0.18
Single floor running
protection time
0~100.0s 45.0
T0.19
Fast arrival opening
delay
0~65535 0
T0.20
Beam keeping failure
time
0~65535s 0
T0.21
Reserved
0~65535 0
…
…
… …
T0.28
Reserved
0~65535 0
F0 Group Function setting
F0.00
High/low voltage
detection
0: Only detect high voltage
1: Only detect low voltage
2: Detect high/low voltage
2
F0.01 Hand door enabling
0: Invalid
1: Arrival without open/closed detection. The
elevator continues to run after switch off the
door lock.
0
F0.02 Closing output delay
0: Do not output closing signal after the door is
closed
0.1~600.0s: closing keeping time after the
door is closed
Set to 600, the door keeps closed
0.5
F0.03 Fire safety mode
0: China fire safety
1: Australia fire safety
2: Britain fire safety
3: Special function for fire safety 2012
0
F0.04
Closing output
condition of dual doors
0: Dual door output closing signal when the
door lock is blocked
1: End the closing command after the door
closed
0