User manual of EC160 elevator intelligent integrated machine Debugging tools
63
Function
code
Name Detailed instruction of parameters
Default
value
F0.15 MF output in the car
0~65535
Unit: Define RDC port of DC01, LED light
corresponding to PAS
Ten: Define RDO port of DC01, LED light
corresponding to DOD
0: Closing/opening output light of rear door
1: Opening delay light
2: Mapping PLC OUT1 (Y5)
3: Mapping PLC OUT2 (Y6)
4: Low speed closing signal
10
F0.16 Test mode
0~65535
1: Allow communication reset at drive fault
8: Close at fast arrival and shield calling
16: Cancel double click number clearance
64: Enable peristaltic UCM protection
0
F0.17
Relative selection of
CAN communication
0~65535
1: Open protocol (Both calling board and car
board are connected to the same line.)
2: OL voltage>FL voltage>LL voltage for
weighing sensor of the car top board
4: Command number clearance after fast stop
at door area, if not, deceleration point number
clearance
16: When the internal calling is open protocol,
the external calling adopts internal protocol
connected to the external calling line or open
protocol connected to the internal calling line
32: Communicating door operator
0

Table of Contents