User manual of EC160 elevator intelligent integrated machine Debugging tools
65
Function
code
Name Detailed instruction of parameters
Default
value
F0.22 UPS application
0~65535
0: 220V power supply (The switching of drive
power supply is controlled by Y6. Set KPWR
input to normally closed logic. Detect UPS
output feedback and bus voltage. After
leveling open delay, disconnect Y6.)
1: 380V power supply (The switching of drive
power supply is controlled by UPS itself. UPS
bus voltage detection is unnecessary. After
leveling open delay, output Y6, KPWR input
optional.)
0
F0.23
DS multi-function
definition in the car
0~65535
0: Original definition
1: Opening keeping delay button
2: Front/rear door selection
3: Car firefighter input
0
F0.24
Dual door area
selection
0~65535
1: Enable dual door area
2: Dual door area replaces slow limit switch
4: Return to leveling and correct pulses in the
state of dual door area
0
F0.25
Reserved
0~65535 0
F0.26
Start time 1 of time
sharing service
0~2359
Thousands and hundreds: Hour
Tens and ones: Minute
0
F0.27
Stop time 1 of time
sharing service
0~2359
Thousands and hundreds: Hour
Tens and ones: Minute
0
F0.28
Time 1 of time sharing
service
Stop at 1~16 floors
0~65535 0