User manual of EC160 elevator intelligent integrated machine Debugging tools
68
Function
code
Name Detailed instruction of parameters
Default
value
F0.63
Rear door 33~48
communicating IC card
open floors
0~65535 0
F0.64
Rear door 49~64
communicating IC card
open floors
0~65535 0
F0.65 Reserved 0~65535 0
… … … …
F0.70
Y5 relay output
definition
0~65535
0: Original definition
1: Output contactor control 1
2: Star-delta output
3: Brake contactor control 1
4: Brake contactor control 2
5: Fire return
6: Front door opening output
7: Front door closing output
8: Rear door opening output
9: Rear door closing output
10: Pre-opening output
11: Low speed signal
12: UPS control
13: Lock return
14: Energy saving output
15: Forced closing output
16: Elevator up signal
17: Elevator down signal
18: Major fault signal
19: Peristaltic UCM protection
20: Reserved
21~99: No definition
0
F0.71
Y6 relay output
definition
F0.72 Reserved 0~65535 0
… … … …