Goodrive100-PV series solar pumping inverters Function parameters
-39-
Function
code
Name
Detailed illustration of parameters
Default
Modify
P06.13
Switch off delay of
RO2
0.000~50.000s
0.000s
P07 Group Human-Machine Interface
P07.02
QUICK/JOG
function selection
0: No function
1: Jogging running. Press QUICK/JOG to
begin the jogging running.
2: Shift the display state by the shifting
key. Press QUICK/JOG to shift the
displayed function code from right to left.
3: Shift between forward rotations and
reverse rotations. Press QUICK/JOG to
shift the direction of the frequency
commands. This function is only valid in
the keypad commands channels.
4: Clear UP/DOWN settings. Press
QUICK/JOG to clear the set value of
UP/DOWN.
5: Coast to stop. Press QUICK/JOG to
coast to stop.
6: Shift the running commands source.
Press QUICK/JOG to shift the running
commands source.
7: Quick commissioning mode (based on
non-factory parameters)
Note: Press QUICK/JOG to shift between
forward rotation and reverse rotation, the
inverter does not record the state after
shifting during powering off. The inverter