Goodrive100-PV series solar pumping inverters Recommended solar modules
-72-
B.2 Recommended configuration for inverters with the boost module
PP100-3R2-PV
+
Solar pumping
inverter
Max. DC
input
current
Open-circuit voltage degree of solar module
37±1V
45±1V
(A)
Module
power±5Wp
Modules per
string * strings
Module
power±5Wp
Modules per
string * strings
GD100-0R4G-SS2-PV
12
250
4*1
300
3*1
GD100-0R7G-SS2-PV
12
250
5*1
300
4*1
GD100-1R5G-SS2-PV
12
250
8*1
300
7*1
GD100-0R4G-S2-PV
12
250
4*1
300
3*1
GD100-0R7G-S2-PV
12
250
5*1
300
4*1
GD100-1R5G-S2-PV
12
250
8*1
300
7*1
GD100-0R7G-4-PV
12
250
5*1
300
4*1
GD100-1R5G-4-PV
12
250
8*1
300
7*1
GD100-2R2G-4-PV
12
250
13*1
300
11*1