Page #44 background imageLoading...
Page #44 background image
Goodrive100-PV series solar pumping inverters Function parameters
-43-
Function
code
Name
Detailed illustration of parameters
Default
Modify
Weak light alarm (A-LS)
Underload alarm (A-LL)
Full water alarm (A-tF)
Water-empty alarm (A-tL)
P08 Group Enhanced functions
P08.28
Times of fault
reset
0~10
5
P08.29
Interval time of
automatic fault
reset
0.1~3600.0s
10.0s
6.2 Parameters of special functions
Function
code
Name
Detailed illustration of parameters
Default
Modify
P11 Group Protective parameters
P11.00
Phase loss
protection
0x000~0x011
LED ones:
0: Input phase loss software protection
disabled
1: Input phase loss software protection
enabled
LED tens:
0: Input phase loss software protection
disabled
1: Input phase loss software protection
enabled
LED hundreds:
Reserved
000~111
Depend
on model