EasyManua.ls Logo

INVT GD100-0R4G-SS2-PV - P15.27 Max. Voltage Reference During Max. Power Tracking; P15.28 Adjustment of Initial Reference Voltage; A.4 Reactors

INVT GD100-0R4G-SS2-PV
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Goodrive100-PV series solar pumping inverters Recommended solar modules
-71-
Appendix B Recommended solar modules
B.1 Recommended configuration for solar pumping inverters
Solar pumping inverter
model
Open-circuit voltage degree of solar module
37±1V
45±1V
Module
power±5Wp
Modules per
string *
strings
Module
power±5Wp
Modules per
string * strings
GD100-0R4G-SS2-PV
250
11*1
300
9*1
GD100-0R7G-SS2-PV
250
11*1
300
9*1
GD100-1R5G-SS2-PV
250
11*1
300
9*1
GD100-2R2G-SS2-PV
250
11*1
300
9*1
GD100-0R4G-S2-PV
250
11*1
300
9*1
GD100-0R7G-S2-PV
250
11*1
300
9*1
GD100-1R5G-S2-PV
250
11*1
300
9*1
GD100-2R2G-S2-PV
250
11*1
300
9*1
GD100-004G-2-PV
250
11*2
300
9*2
GD100-5R5G-2-PV
250
11*3
300
9*3
GD100-7R5G-2-PV
250
11*4
300
9*4
GD100-0R7G-4-PV
250
18*1
300
15*1
GD100-1R5G-4-PV
250
18*1
300
15*1
GD100-2R2G-4-PV
250
18*1
300
15*1
GD100-004G-4-PV
250
20*1
300
16*1
GD100-5R5G-4-PV
250
18*2
300
15*2
GD100-7R5G-4-PV
250
18*2
300
15*2
GD100-011G-4-PV
250
18*3
300
15*3
GD100-015G-4-PV
250
18*4
300
15*4
GD100-018G-4-PV
250
18*5
300
15*5
GD100-022G-4-PV
250
18*6
300
15*6
GD100-030G-4-PV
250
18*8
300
15*8
GD100-037G-4-PV
250
18*9
300
15*9

Related product manuals