Goodrive200A inverters Function parameters
73
Function
code
Name Detailed instruction of parameters
Default
value
factory value changes with voltage level.
The setting range:200.0~2000.0V
In order to prevent customers set the value is too
large, it is recommended setting range:
voltage
Cooling fan
running
mode
Set the operation mode of the cooling fan.
0: Normal mode, after the rectifier receives
operation command or the detected temperature
of module is above 45℃ or the module current is
above 20% of the rated current, the fan rotates.
1:The fan keeps on running after power on
(generally for the site with high temperature and
humidity)
0 ○
P08.40
0x00~0x21
LED ones: PWM mode selection
0: PWM mode 1, three-phase modulation and
two-modulation
1: PWM mode 2, three-phase modulation
LED tens: low-speed carrier frequency limit mode
0: Low-speed carrier frequency limit mode 1, the
carrier frequency will limit to 2k if it exceeds 2k at
low speed
1:Low-speed carrier frequency limit mode 2, the
carrier frequency will limit to 4k if it exceeds 4k at
low speed
2: No limit
00
◎
P08.41
Over
commission
selection
0x00~0x11
LED ones
0: Invalid
1: Valid
LED tens
0: Light overcommission
1: Heavy overcommission
0x01
◎
P08.42
0x000~0x1223
LED ones:frequency enable selection
0:Both ∧/∨ keys and digital potentiometer
adjustments are valid
1:Only ∧/∨ keys adjustment is valid
0x0000