Goodrive18 series two-in-one VFD Function parameters and function terminal reuse
-69-
Function
code
Name
Description
Default
value
Modify
P07.34
Ramp reference frequency at present fault
0.00Hz
P07.35
Output voltage at present fault
0V
P07.36
Output current at present fault
0.0A
P07.37
Bus voltage at present fault
0.0V
P07.38
Max. temperature at present fault
0.0°C
P07.39
Input terminal status at present fault
0
P07.40
Output terminal status at present fault
0
P07.41
Running frequency at last fault
0.00Hz
P07.42
Ramp reference frequency at last fault
0.00Hz
P07.43
Output voltage at last fault
0V
P07.44
Output current at last fault
0.0A
P07.45
Bus voltage at last fault
0.0V
P07.46
Max. temperature at last fault
0.0°C
P07.47
Input terminal status at last fault
0
P07.48
Output terminal status at last fault
0
P07.49
Running frequency at 2nd-last fault
0.00Hz
P07.50
Ramp reference frequency at 2nd-last fault
0.00Hz
P07.51
Output voltage at 2nd-last fault
0V
P07.52
Output current at 2nd-last fault
0.0A
P07.53
Bus voltage at 2nd-last fault
0.0V
P07.54
Max. temperature at 2nd-last fault
0.0°C
P07.55
Input terminal status at 2nd-last fault
0
P07.56
Output terminal status at 2nd-last fault
0
P08 Enhanced functions
P08.00
ACC time 2
For details, see P00.11 and P00.12.
Goodrive18 series VFD defines four groups of
acceleration/deceleration time, which can be
selected by multifunction digital input terminals
(P05 group). The acceleration/deceleration time
of the VFD is the first group by default.
Setting range: 0.03600.0s
Model
depended
P08.01
DEC time 2
Model
depended
P08.02
ACC time 3
Model
depended
P08.03
DEC time 3
Model
depended
P08.04
ACC time 4
Model
depended
P08.05
DEC time 4
Model
depended

Table of Contents