2.78 ZONE CALL AND CONNECTION NUMBER LIMIT
2.78.1 Zone Outgoing CO call Number Limit
Description
Every system has a limited number of CO lines and all devices share those CO lines. The
number of CO lines may be smaller than the number of other devices. If some devices use all
the CO lines, the other devices can not call outside of the system. To prevent this situation and
to increase the common usage of the CO lines, outgoing CO calls are limited to a zone
maximum outgoing CO call number. Zone maximum outgoing CO call number can be set from
0 to maximum CO line capacity. The default value of zone maximum outgoing CO call number
is 0 and it means there is no limit to zone outgoing CO call.
Operation
Operation of this feature is automatic based on zone maximum outgoing CO call number.
Conditions
1. If maximum outgoing CO call number is set to 0, zone outgoing CO call will not be
limited.
2. If maximum outgoing CO call number is set to non-zero value and current zone
outgoing CO call number is more than maximum value, the outgoing CO call trying
station will play error tone and displayOUTGOING CALL LIMIT OVER” on the
LCD.
3. Networking call is also processed as an outgoing CO call.
4. System counts emergency call in current outgoing CO call number, but no limit
procedure is applied.
Programming
ZONE DATA
Zone Attributes (PGM 439-Web only)
Related Features
Hardware
2.78.2 Inter Zone Connection Number Limit
Description
If some devices exist very far from the other devices, it might cause to the bandwidth limitation.
Those devices must be controlled the number of connections according to the bandwidth
limitation for the voice quality. Inter zone connections are limited to zone maximum total inter
zone connection number and maximum inter zone connection number between zones.
Zone maximum total inter zone connection number and maximum inter zone connection
number can be set from 0 to maximum station capacity. The default values of both numbers

Table of Contents