CLEANING THE CELL cycle
CLEANING THE CELL
COLD
FUNCTIONS
HOT
FUNCTIONS
+3°C
?
START
0h:30
CLEANING THE CELL
0h:20
SAVE
- +
+
?
0:15:28
+8°C
STOP
CLEANING THE CELL
Select CLEANING THE CELL cycle.
User guide
Press the
key to view a short description as information window. The
key makes you go back to the previous page.
The key makes you go back to the initial screen.
START
Start cycle.
The temperature inside the chamber detected by the air probe is shown at
the top right-hand side .
Cleaning cycle time, 30 min. by default, is displayed in the middle of the
screen (time can be edited during operation by pressing on the central active
area).
The screen for cleaning time setting will appear. (cleaning time can be set
from 20 min. to 60 min.).
To edit the time press the
+
-
keys to increase or decrease the time by 1
minute. If you wish to increase or decrease the time in a faster manner, use
the horizontal dragging.
Press the
SAVE
key to conrm the time modication, while press
to go
back to the previous screen without saving any change.
Press the
START
key to start the cycle. During the cycle in progress, to be
carried out with open door, the cycle time left (in hours and minutes) will
be displayed. After 5 min. from cycle start, the appliance emits a sound
signal and an information window with a button at the bottom
OK
of the
screen will appear. During this phase, spray the neutral detergent inside the
chamber to sanitise it. Spray the product on all inner surfaces except the
fan. After pressing
OK
do not close the door and wait for 5 minutes before
starting cleaning again. Press
STOP
for 1 sec. or you will go back to the initial
screen once cycle time is elapsed.
Note:
It is recommended to carry out a chamber cleaning cycle after every use. However, it is compulsory (otherwise
the salubrity of the appliance will be compromised) to carry out a cleaning cycle for the recommended time of
30 minutes when switching from a cold to a hot cycle, always keeping the door open. Dry the inner walls and the
bottom of the chamber with a cloth. At the end of the cleaning cycle it is possible to nd some water droplets, so
make sure to dry all of them to avoid the formation of mould and bad smells during downtime.
It is recommended to keep the door ajar when FREDDY is not used. This is to facilitate aeration of the camber and
evaporation of any residual humidity. After cleaning we recommend rinsing and drying the inside of the chamber
with care.