52 Freddy
READY MEAL cycle
MANUAL cycle (with timer)
Select HOT FUNCTIONS.
HOT
FUNCTIONS
Select READY MEAL cycle.
Select MANUAL WITH TIMER Key.
User guide
Press the
key to view a short description as information window. The
key makes you go back to the previous page.
The key makes you go back to the initial screen.
START
Start cycle.
The temperature inside the chamber detected by the air probe is shown at
the top right-hand side .
The heating phase time, 2 h by default, is shown on the left. The air
temperature inside the chamber during reviving phase, +65 °C by default, is
shown in the middle of the screen. The time you wish the food to be ready,
which is zero by default, is shown on the right.
Press the key to access the screen for time setting during reviving
phase. The screen for ready meal cycle time setting, which is 2 h by default,
will be displayed. (the ready meal cycle time can be set from 1 min. to 5 h).
To edit the time press the
+
-
keys to increase or decrease the time by 1
minute. If you wish to increase or decrease the time in a faster manner, use
the horizontal dragging.
Press the
SAVE
key to conrm the time modication, while press
to go
back to the previous screen without saving any change.
AUTOMATIC
WITH CORE
PROBE
TIMED
MANUAL
2h:00 65°C 13:15
?
START
+3°C
3h:30
SAVE
- +
+