Freddy 53
46°C
SAVE
- +
+
Press the key to access the screen for chamber temperature setting
during reviving phase.
The screen for chamber temperature setting during reviving phase, +65 °C
by default, will be displayed (ready meal cycle temperature can be set from
+40 °C to +85 °C). To edit the temperature press the
+
-
keys to increase
or decrease the temperature by 1 °C. If you wish to increase or decrease the
temperature in a faster manner, use the horizontal dragging.
Press the
SAVE
key to conrm the temperature modication, while press
to go back to the previous screen without saving any change.
Press to access the time editing screen to set the time you wish the
food to be ready.
The delay time setting screen, i.e. the time you wish the food to be ready, will
appear. The minimum value that can be displayed and set is zero, while the
maximum value is 48 h, including ready meal cycle (by changing the time, the
initial cold storage (+2 °C) phase time is increased before reviving phase).
To edit the time press the
+
-
keys to increase or decrease the time by 1
minute. If you wish to increase or decrease the time in a faster manner, use
the horizontal dragging.
Press the
SAVE
key to conrm the time modication, while press to go
back to the previous screen without saving any change.
Press the
START
key to start the cycle. During the cycle in progress, until
heating phase has not started, the time left (countdown) of the cold storage
(+2 °C) will be displayed. This time can be edited by pressing .
The screen to change the time you wish the food to be ready will appear; this
screen acts on the cold storage (+2 °C) time, as the reviving phase has not
started yet.
To edit the time press the
+
-
keys to increase or decrease the time by 1
minute. If you wish to increase or decrease the time in a faster manner, use
the horizontal dragging.
Press the
SAVE
key to conrm the time modication, while press to go
back to the previous screen without saving any change.
The chamber temperature detected by the air probe is shown at the top
right-hand side of the display .
13:15
SAVE
- +
+
?
0:22:25
+2°C
STOP
13:15
SAVE
- +
+
2h:00 65°C 13:15
?
START
+3°C