30 Freddy
FREEZING -18 °C cycle
Manual CYCLE (with timer)
Select COLD FUNCTIONS.
COLD
FUNCTIONS
Select FREEZING -18 °C cycle.
Select MANUAL WITH TIMER Key.
User guide
Press the
key to view a short description as information window. The
key makes you go back to the previous page.
The key makes you go back to the initial screen.
START
Start cycle.
The temperature inside the chamber detected by the air probe is shown at
the top right-hand side .
The freezing -18 °C time, 2 h by default, is shown in the middle. Press on the
central active area to access the time editing screen.
The freezing time setting screen will appear.
The minimum value that can be displayed and set is 1 min., while the
maximum value is 5 h.
To edit the time press the
+
-
keys to increase or decrease the time by 1
minute. If you wish to increase or decrease the time in a faster manner, use
the horizontal dragging.
Press the
SAVE
key to conrm the time modication, while press
to go
back to the previous screen without saving any change.
Press the
START
key to start the freezing -18 °C cycle.
During operation the display shows the freezing cycle time left (in hours and
minutes) that can be edited by selecting .
You will access the time editing screen which is the same described above.
AUTOMATIC
WITH CORE
PROBE
TIMED
MANUAL
+3°C
?
START
2h:00
3h:30
SAVE
- +
+
+3°C
?
START
1h:30