Freddy 7
If the power cable is damaged, it must be
replaced by the manufacturer, dealer or
qualied personnel to avoid potential risks.
Do not use the appliance inside compartments
used for food storing, if they are not
recommended by Irinox SPA.
This appliance is not suitable to store and cool
medicines, plasma, laboratory samples,
substances and similar products indicated in
the medical devices directive. Irinox SPA is not
to be held liable for damages caused by a use
dierent from the intended one or by wrong
settings.
The cooling circuit is a sealed circuit containing
propane (R290), a natural gas which is
ecological but ammable.
For this reason, pay attention not to damage
any component of the cooling circuit during
appliance transport and installation.
In case of damaging:
- Avoid naked ames or ignition sources.
- Disconnect the appliance from the power
mains.
- Aerate the room for a few minutes.
- Warn the technical assistance service.
According to the characteristics of the
refrigerant used in the circuit, we recommend
to install the appliance in an environment with
the right ratio between refrigerant charge and
room volume, which should be of at least 8g
per cubic meter of volume.
The quantity of refrigerant used in the circuit
can be found on the appliance data plate.