TM3160F,TM3200F&TM3240F
64
ELECTRICAL SYSTEM
Battery
FIG. 94: Battery (1) is located under the engine hood
in front of the radiator. If the battery requires only minor
servicing or charging, it is recommended that the front
grille be removed to reach the battery. When the battery
is removed, electrolyte inspection or cable cleaning is
necessary, the front grille must be removed from the trac-
tor. Keep top of the battery clean and ensure cable con-
nections are clean and tight. Debris on the battery can
cause discharge of the battery and be a possible source
of fire.
CAUTION: Batteries produce explosive
hydrogen when they have charged. Keep all
sparks and open flames away from the bat-
tery. When necessary to disconnect battery
cables, always disconnect the earthed (-)
cable first to prevent short circuits. Batteries
contain sulfuric acid electrolyte fluid. Wear
eye and face protection. If electrolyte comes
in contact with skin or clothes, wash immedi-
ately. Contact a physician immediately if
electrolyte is ingested or gets in eyes.
FIG. 95: Tractors are shipped with the battery
installed. If battery replacement should become neces-
sary, disconnect the negative (-) cable (1) first and then
remove the positive (+) cable (2). Loosen and remove the
battery securing clamp and carefully remove the battery
from the tractor.
When installing the battery, the cable (2) connected
to the starter solenoid should be connected to the positive
(+) battery terminal first then the cable (1) earthed to the
tractor frame can be connected to the negative (-) battery
terminal.
NOTE: Make sure the replacement battery is of identi-
cal size and equal capacity.
IMPORTANT: Do not reverse battery cable connections
as severe electrical system damage will
result.
FIG. 94
FIG. 95