Technical Specification
Voltage programming
External 0V~10V is 0~60V
Voltage monitoring
External 0V~10V is 0~60V
Calculation method of resistance precision range in load mode: lower limit: 1/(1/
R+(1/R)*0.05+0.004) ; Upper limit: 1/(1/R-(1/R)*0.05-0.004)
10.2 IT-M3322
Parameter IT-M3322 V1.2
Load Parameter
Rated value
( 0 ℃-40
℃)
Input Voltage
0-60V
Input Current
0-30A
Input Power
0-400W
Min. operating voltage
1V at 30A
CC
Range
0-30A
Setup Resolution
10mA
Accuracy
≤0.1%+0.1%FS
CV
Range
0-60V
Setup Resolution
1mV
Accuracy
<0.1% Umax
CR
Range
0.04-600Ω
Resolution Min.0.001Ω
Accuracy
(1/Rmin)*2%: (0.04~60Ω), (1/Rmin)*5%: (60~600Ω)
CP
Range
0-400W
Setup Resolution
0.1W
Accuracy
<1.0% Pmax
Dynamic
mode
Rising slope
30A/ms
Falling slope
30A/ms
Min. rise time 1ms
Input Read-back
Read-back
current
Range
0-30A
Resolution 1mA
Accuracy
≤0.1%+0.1%FS
Read-back
Voltage
Range
0-60V
Resolution 1mV