Technical Specification
Storage temperature
-20- 70℃
Noise 60dB
External temperature measurement
Measurement range
-20℃——120℃
Measurement accuracy
±1℃
Measurement resolution 0.1℃
Efficiency
Max. efficiency (Full-
load)
86%
Communication(Optional)
Communica-
tion
interfaces
RS232/USB/RS485/CAN/LAN/GPIB/Analog
Mechanical parameters
Size and
weight
450mm*214mm*43.5mm
Net weight 5kg
Calculation method of resistance precision range in load mode: lower limit: 1/(1/
R+(1/R)*0.05+0.004) ; Upper limit: 1/(1/R-(1/R)*0.05-0.004)
10.3 IT-M3332
Parameter IT-M3332 V1.2
Load Parameter
Rated value
( 0 ℃-40
℃)
Input Voltage
0-60V
Input Current
0-30A
Input Power
0-800W
Min. operating voltage
1V at 30A
CC
Range
0-30A
Setup Resolution
10mA
Accuracy
≤0.1%+0.1%FS
CV
Range
0-60V
Setup Resolution
1mV
Accuracy
<0.1% Umax
CR
Range
0.04-600Ω
Resolution Min.0.001Ω