4 Programming the Input
♦ Select the Operation Mode (Mode)
♦ Single Operation Mode
♦ Complex Operation Mode
♦ Battery simulation mode
♦ Set I-Rise / I-Fall Slope
♦ Set the Input-On/Input-Off Delay Time
♦ Enable the Input
4.1 Select the Operation Mode (Mode)
There are eight modes of operation, such as CC, CV, CR, CP, CV+CC, CV
+CR, CC+CR, CC+CV+CP+CR and Battery Sim., the operation mode can de
divided to basic operation modes and complex operation modes according to
function types. Battery Sim. is battery test mode.
• Basic operation modes: CC (constant current), CV (constant voltage), CP (-
constant power), CR (constant resistance);
• Complex operation modes: CV+CC, CV+CR, CC +CR, CV+CC+CP+CR;
The procedures to select the operation mode are as follows.
1. Press [Shift]+[V-set](Config) to enter into configuration menu.
1:Mode=CC
2. Rotate the knob and select 1:Mode=CC and press [Enter] to confirm.
3. Rotate the knob to switch Mode value.
For example, select CV and press [Enter] to confirm, the instrument under
the CV mode.
4. Press [Esc] to exit.
At this time, the [V-set] key light will be lit. Press [V-set] key to set the input
voltage.
• When select a single mode in Config menu such as CC/CV/CR/CP. The
[V-set]/[I-set]/[R-set]/[P-set] keys can switch the CV/CC/CR/CP mode.
For example, under CV mode, if you press [I-set] key, the present mode
switch to CC mode and set the input current value.
• When select a complex mode in Config menu, if you press
[V-set]/[I-set]/[R-set]/[P-set] keys on front panel, the present mode can
not be changed. Under this mode, the corresponding setting keys light
Copyright © Itech Electronic Co., Ltd.