EasyManua.ls Logo

ITech IT-M3300 Series - Page 119

ITech IT-M3300 Series
135 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Specification
Temperature Coefficient
Temperature
Coefficient
Voltage Temperature
Coefficient
100ppm/℃
Current Temperature
Coefficient
50ppm/℃
Protection range
OCP 6.2A
OVP 310V
OPP 210W
Short circuit test
Current 6.6A
External analog (optional)
Current programming
External 0V~10V is 0~6A
Current monitoring
External 0V~10V is 0~6A
Voltage programming
External 0V~10V is 0~300V
Voltage monitoring
External 0V~10V is 0~300V
AC parameters
Voltage range
100VAC -240VAC
OVP 264VAC
UVP 90VAC
Frequency
47Hz~63Hz
Max. current (rms) 1Aac (AC220V)
DC Offset
-0.1A~+0.1A
Environment
Working temperature
0- 40 °C
Storage temperature
-20- 70℃
Noise 60dB
External temperature measurement
Measurement range
-20℃——120℃
Measurement accuracy
±1℃
Measurement resolution 0.1℃
Efficiency
Max. efficiency (Full-load)
88%
Communication(Optional)
Communication interfaces
RS232/USB/RS485/CAN/LAN/GPIB/Analog
Mechanical parameters