Technical Specification
Temperature Coefficient
Temperature
Coefficient
Voltage Temperature
Coefficient
100ppm/℃
Current Temperature
Coefficient
50ppm/℃
Protection range
OCP 3.1A
OVP 610V
OPP 810W
Short circuit test
Current 3.3A
External analog (optional)
Current programming
External 0V~10V is 0~3A
Current monitoring
External 0V~10V is 0~3A
Voltage programming
External 0V~10V is 0~600V
Voltage monitoring
External 0V~10V is 0~600V
AC parameters
Voltage range
100VAC -240VAC
OVP 264VAC
UVP 90VAC
Frequency
47Hz~63Hz
Max. current (rms) 4Aac (AC220V)
Power factor PF
>0.98(Lead or Lag)
DC Offset
-0.1A~+0.1A
Harmonic THDI <5%
Environment
Working temperature
0- 40 °C
Storage temperature
-20- 70℃
Noise 60dB
External temperature measurement
Measurement range
-20℃——120℃
Measurement accuracy
±1℃
Measurement resolution 0.1℃
Efficiency
Max. efficiency (Full-load)
88%
Communication(Optional)