Page #116 background image
Basic Operation
Category
Parameter Initial Value
[On/Off] status Off
System
menu
Beep On
PowerOn Reset
Sense Off
ListTrig Source Manual
DataLogger Trig Source Manual
I/O Con USB-VCP
Digital Port
IO–1: Ps-Clear
IO–2: Ps
IO–3: Off-Status
IO–4: Trig(In)
IO–5: INH-Living
IO–6: Sync-On
IO–7: Sync-Off
Parallel Single
Config
menu
Mode CV
Speed High
V-Rise Time/I-Rise Time 0.1s
V-Fall Time/I-Fall Time
Output Res 1000
On Delay/Off Delay 0
Protect
menu
OVP/OCP/OPP/UCP/UVP Sta-
tus switch
Off
OVP/OCP/OPP Protection point:
Level
Rated voltage / current /
power value of the
instrument
UCP/UVP Protection point:
Level
0
OVP/OCP/OPP/UCP/UVP Delay
time: Delay
60s