EasyManua.ls Logo

ITech IT-M3900D Series - M3902 D-500-12

ITech IT-M3900D Series
199 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Specification
Isolation AC to GND 3500Vdc
Cooling
Air
Dimension
D*W*H
767.62mm*483mm*106.9mm
Weight( net) 30kg
*1: At low voltage input, the set power will decrease. For more information,
please contact ITECH.
6.1.17 IT-M3902D-500-12
Parameter IT-M3902D-500-12
Rated value
Voltage
0500V
Current 0A12A
Power 0W2000W
Resistance in series
CV priority
01Ω
Setup Resolution
Voltage
0.01V
Current 0.001A
Power 1W
Resistance in series
CV priority
0.01Ω
Read Back
Resolution
Voltage
0.01V
Current 0.001A
Power 1W
Setup Accuracy
Voltage
≤0.03% + 0.03%FS
Current ≤0.1% + 0.1%FS
Power ≤0.5% + 0.5%FS
Resistance in series
CV priority
≤1%FS
Read Back
Accuracy
Voltage
≤0.03% + 0.03%FS
Current ≤0.1% + 0.1%FS
Power ≤0.5% + 0.5%FS
Voltage ripple
*1
Vp-p ≤1500mVpp
Vrms ≤180mV
Copyright © Itech Electronic Co., Ltd.