Basic Operation
The procedures to set the menu item are as follows.
1. Press the composite keys [Shift]+[P-set] (System) on the front panel to en-
ter the system menu.
2. Turn the knob to select the Sense and press [Enter].
3. Press the Left / Right key or turn the knob to adjust the value of this
parameter.
• Off: Default value, indicates turn the sense function off.
• On: Indicates turn the sense function on.
4. After the parameter settings are complete, press [Enter].
5.8 Select Trigger Source (Trig Source)
For this series power supply, the List and data logging functions can be trig-
gered for running by the following methods:
• Immediate: Perform a trigger operation immediately.
• Manual: Default value, indicates the trigger occurs when the
[Shift]+[On/Off] (Trigger) keys are pressed from the front panel.
• Bus: Indicates the trigger occurs via the communication cables. When the
trigger command *TRG is received, the instrument generates a trigger.
• Voltage (only available in DLogTrig Source): Voltage trigger.
When the DC terminals detect that the voltage reaches the trigger voltage
setting value and is within the range of the upper and lower trigger limits, a
data recording operation is triggered.
– Level: Trigger threshold.
– Up-Level: Trigger upper limit value.
– Down-Level: Trigger lower limit value.
• Current (only available in DLogTrig Source): Current trigger.
When the DC terminals detect that the current reaches the trigger current
setting value and is within the range of the upper and lower trigger limits, a
data recording operation is triggered.
– Level: Trigger threshold.
– Up-Level: Trigger upper limit value.
– Down-Level: Trigger lower limit value.