Basic Operation
1. Press the composite keys [Shift]+[Recall] (Save) to enter the parameter
save interface. (1U Model)
2. Press the composite keys [Shift]+[+/-] (Save) to enter the parameter save
interface. (2U Model)
3. Set the storage location.
Enter a number in the "Save data to bank=1" to set the storage location in
non-volatile memory.
4. Press [Enter] to save the parameters.
5.3.2 Recall Operation
You can recall the parameters you saved in the specified memory location as
the setting values.
1. Press [Recall] to enter the parameter recall interface.
2. Set the storage location.
Enter a number in the “Recall data from bank=1” to set the storage location
in non-volatile memory.
3. Press [Enter] to recall the parameters.
5.4 Data Logging Function
This series High power Programmable DC Power Supply supports the recording
and saving of test data. This Chapter introduces how to use this function in
details.
The user can select the following data sources for recording:
• Voltage
Only records voltage data during the data acquisition period.
• Current
Only records current data during the data acquisition period.
• Voltage and current
Records current and voltage data during the data acquisition period.
Configure the Function Menu
1. Press the composite button [Shift]+[1] (Log) on the front panel to enter the
configuration menu of the data logging function.