Technical Specification
Parameter IT-M3902D-32-80
Current ≤0.03% + 0.03%FS
Load Regulation
Voltage
≤0.02% + 0.02%FS
Current ≤0.05% + 0.05%FS
Output protection
OCP 83A
OVP 33V
Overpower
protection
2040W
Remote Sense
Compensation
Voltage
≤2V
External analog
(optional)
current program
External programming voltage 0V to 10V corre-
sponds to current 0A to 80A
current monitor
Current 0A to 80A corresponds to external monitor-
ing voltage 0V to 10V
voltage program
External programming voltage 0 to 32V Corre-
sponding voltage 0 to 10V
voltage monitor
Voltage 0 to 32V corresponds to external monitor-
ing voltage 0 to 10V
Other parameters:
AC Input
*2
Grid voltage range
3phase 200V~480V
Single phase 100V~240V
Frequency
50/60Hz
Max. apparent
power
2.25kVA
Max. input current
12.5Aac
Max. efficiency
92%
Power Factor 0.99
DC component
≤0.2A
Current harmonics ≤3%
Standard Interface
Standard: USB/LAN/CAN/IO
Optional: GPIB/Analog&RS232
Command Re-
sponse Time
0.1ms
Parallel Number ≤16
Working
Temperature
0~40℃
Copyright © Itech Electronic Co., Ltd.