Technical Specification
Parameter IT-M3904D-300-40
Remote Sense
Compensation
Voltage
≤3V
External analog
(optional)
current program
External programming voltage 0V to 10V corre-
sponds to current 0A to 40A
current monitor
Current 0A to 40A corresponds to external moni-
toring voltage 0V to 10V
voltage program
External programming voltage 0 to 300V Corre-
sponding voltage 0 to 10V
voltage monitor
Voltage 0 to 300V corresponds to external moni-
toring voltage 0 to 10V
Other parameters:
AC Input
*2
Grid voltage range
3phase 200V~480V
Single phase 100V~240V
Frequency
50/60Hz
Max. apparent power
4.5kVA
Max. input current
12.5Aac
Max. efficiency
94.5%
Power Factor 0.99
DC component
≤0.2A
Current harmonics ≤3%
Standard Interface
Standard: USB/LAN/CAN/IO
Optional: GPIB/Analog&RS232
Command Response
Time
0.1ms
Parallel Number ≤16
Working
Temperature
0~40℃
Storage
Temperature
-10℃~70℃
IP IP20
Isolation DC to GND 600Vdc
Isolation AC to GND 3500Vdc
Cooling
Air
Copyright © Itech Electronic Co., Ltd.