Technical Specification
Parameter IT-M3906D-800-24
Read Back
Accuracy
Voltage
≤0.03% + 0.03%FS
Current ≤0.1% + 0.1%FS
Power ≤0.5% + 0.5%FS
Voltage ripple
*1
Vp-p ≤1000mVpp
Vrms ≤160mV
Setup Temperature
Coefficient
Voltage ≤30ppm/℃
Current
≤50ppm/℃
Read Back Temper-
ature Coefficient
Voltage ≤30ppm/℃
Current
≤50ppm/℃
Rise Time( no load ) Voltage
≤30ms
Rise Time( full load ) Voltage
≤60ms
Fall Time( no load ) Voltage
≤1s
Fall Time( full load ) Voltage
≤100ms
Transient Response
Time
(change from 25%
to 90% of rated
current)
Voltage
≤1ms
Line Regulation
Voltage
≤0.01% + 0.01%FS
Current ≤0.03% + 0.03%FS
Load Regulation
Voltage
≤0.01% + 0.01%FS
Current ≤0.05% + 0.05%FS
Output protection
OCP 25A
OVP 808V
Overpower
protection
6120W
Remote Sense
Compensation
Voltage
≤8V
External analog
(optional)
current program
External programming voltage 0V to 10V corre-
sponds to current 0A to 24A
current monitor
Current 0A to 24A corresponds to external moni-
toring voltage 0V to 10V
voltage program
External programming voltage 0 to 800V Corre-
sponding voltage 0 to 10V
voltage monitor
Voltage 0 to 800V corresponds to external monitor-
ing voltage 0 to 10V
Copyright © Itech Electronic Co., Ltd.