Power Supply Function
addition, the power supply also provides over temperature protection and Sense
reverse connection protection.
The descriptions of Protect menu are listed in the table below.
Protect
Protection function menu for the power supply
OVP
Overvoltage protection
Off
Turn the OVP function off. (Def)
On Turn the OVP function on.
Level OVP limit
Delay
Protection delay time,
see Protection Delay.
OCP
Overcurrent protection
Off
Turn the OCP function off. (Def)
On Turn the OCP function on.
Level OCP limit
Delay
Protection delay time,
see Protection Delay.
OPP
Overpower protection
Off
Turn the OPP function off. (Def)
On Turn the OPP function on.
Level OPP limit
Delay
Protection delay time,
see Protection Delay.
UCP
Undercurrent protection
Off
Turn the UCP function off. (Def)
On Turn the UCP function on.
Warm-up
Indicates the instrument
warm-up time. This time
is set to prevent the in-
strument from triggering
protection when the cur-
rent is rising. Because
this transient condition
should not be
Copyright © Itech Electronic Co., Ltd.
47

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT-M3900D Series and is the answer not in the manual?

ITech IT-M3900D Series Specifications

General IconGeneral
BrandITech
ModelIT-M3900D Series
CategoryPower Supply
LanguageEnglish

Related product manuals