Basic Operation
• On: Turns on the external analog function.
In this state, the channel parameters cannot
be set.
• Off: Turns off the external analog function.
In this state, the channel parameters can be
set.
Ch1 Set the parameters of channel 1.
M1 Indicates the slope factor of channel 1.
Mb Indicates the offset of channel 1.
Ch2 Set the parameters of channel 2.
M2 Indicates the slope factor of channel 2.
Mb Indicates the offset of channel 2.
Ch3 Set the parameters of channel 3.
M3 Indicates the slope factor of channel 3.
Mb Indicates the offset of channel 3.
3.6.9 Restored to Factory Setting (System Reset)
This menu item is used to restore some parameter settings to factory setting
values.
The procedures to set the menu item are as follows.
1. Press the composite keys [Shift]+[P-set] (System) on the front panel to en-
ter the system menu.
2. Press the Up/Down key or turn the knob to select the System Reset and
press [Enter].
3. Press the Left / Right key or turn the knob to adjust the value of this
parameter.
• No: Default value, indicates the instrument cancels this menu setting.
• Yes: Indicates the instrument restores the factory default settings.
4. After the parameter settings are complete, press [Enter].
The parameters affected by System Reset and the parameter values after
reset are shown in Table 3–3 Initial value of the parameter.
Copyright © Itech Electronic Co., Ltd.
57
ООО "Техэнком" Контрольно-измерительные приборы и оборудование www.tehencom.com