Basic Operation
Category Parameter Initial Value
MDNS/PING/Telnet-
scpi/Web/VX-11/
Raw-socket: On
VCP: 9600,8,N,1
(Optional) RS232:
9600,8,N,1
(Optional) External
analog: Off
(Optional) GPIB: Ad-
dress=1
Digital Port
IO–1: Ps-Clear
IO–2: Ps
IO–3: Off-Status
IO–4: Ext-Trig
IO–5: INH-Living
IO–6: Sync-On
IO–7: Sync-Off
Parallel Single
Config
menu
Mode CV
Speed High
V-Rise Time/I-Rise Time 0.1s
V-Fall Time/I-Fall Time
Output Res 1000
On Delay/Off Delay 0
Protect
menu
OVP/OCP/OPP/UCP/UVP Sta-
tus switch
Off
OVP/OCP/OPP Protection point:
Level
Rated voltage / current /
power value of the
instrument
UCP/UVP Protection point:
Level
0