Power Supply Function
Press [Esc] key to return to the previous menu level.
The descriptions of configuration menu are listed in the table below.
Config Configuration menu of the power supply
Mode
CC/CV priority mode setting
CV
Constant voltage loop priority mode
Speed= High/Low
Loop response
speed setting:
high speed /
low speed
CC
Constant current loop priority mode
Speed= High/Low
Loop response
speed setting:
high speed /
low speed
V-Rise Time/I-Rise Time
= 0.001s
Displays the voltage or current rise time
setting according to the selected priority
mode. If CC priority mode is selected,
the parameter setting of I-Rise Time will
be displayed here.
V-Fall Time/I-Fall Time =
0.001s
Displays the voltage or current fall time
setting according to the selected priority
mode. If CC priority mode is selected,
the parameter setting of I-Fall Time will
be displayed here.
Output Res
Set the internal resistance of the power
supply. This parameter needs to be set
only when Mode is set to CV.
On Delay Set the delay time to turn on the output.
Off Delay Set the delay time to turn off the output.
Copyright © Itech Electronic Co., Ltd.
66