Technical Specification
5. Up time and down time mean the time of establishment from one value to
another value under ON status when the internal standard power dissipater is
enabled.
6. Use 12V/120AH battery for test.
7. When used in parallel, to balance power of each phase, distribute the
instrument to three phases. But must ensure that single machine input voltage
meets Specification requirements.
8. It means the maximum phase current value under minimum work input
voltage.
5.1.18 IT6537C
Parameter IT6537C Ver:V1.4
Output Rating ( 0 -40
)
Output Voltage
01000V
Output Current
020A
Internal Sink
Current
1
03A
Output Power
06KW
Internal Sink
Power
1
0100W
Output Resistance
Range
0166.666Ω
Accuracy
2
0.25%+375mΩ*A
Resolution 10mΩ
Line regulation Voltage
≤0.01%+100mV
±(of Output+Offset)
Current ≤0.01%+10mA
Load regulation Voltage
≤0.01%+375mV
±(of Output+Offset)
Current ≤0.05%+20mA
Setup Resolution
Voltage
100mV
Current 1mA
Power 0.1W
Read Back Resolution
Voltage
100mV
Current 1mA
Power 0.1W
Setup Accuracy
3
Voltage
≤0.05%+375mV
within 12 months,25
±5)
Current ≤0.2%+20mA
Copyright © Itech Electronic Co., Ltd.
139

Table of Contents

Other manuals for ITech IT6500C Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6500C Series and is the answer not in the manual?

ITech IT6500C Series Specifications

General IconGeneral
BrandITech
ModelIT6500C Series
CategoryPower Supply
LanguageEnglish

Related product manuals