Function and Features
12V Select the 12V waveform
24V Select the 24V waveform
User-defined User defined waveform
Off
Disable/Enable the automotive
starting waveform function.
On
ISO16750-
2
simulate the waveform to verify the anti-interference
performance of the automotive electronics’ products.
Short-Drop
This test simulates the effect when a
conventional fuse element melts in
another circuit
12V
Select 12V or 24V
waveform
24V
Off Enable or Disable
the Short voltage
drop function.
On
Reset-Test
This test verifies the reset behavior
of the DUT at different voltage drops.
This test is applicable to equipment
with reset function
Usmin…
The minimum supply
voltage Usmin
(Usmin≤80V)
Off
Enable/Disable this
functionOn
Starting-
Profile
This test verifies the behavior of a
DUT during and after cranking.
12V
Select 12V or 24V
test system
24V
1
Set the levels/
voltages/duration of
starting profile
The levels of 12V: 1-4
The levels of 24V: 1-3
Off
Enable/Disable this
function
Copyright © Itech Electronic Co., Ltd.