EasyManua.ls Logo

ITech IT8731

ITech IT8731
133 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SOURce Subsystem
Copyright © Itech Electronic Co., Ltd. 90
Parameters
MINimum through MAX | MINimum | MAXimum | DEFault
Unit
W (power)
*RST Value
MINinum
Examples
POW 5 POW:LEV 3.5
Query Syntax
[SOURce:]POWer[:LEVel][:IMMediate]? [ MINimum | MAXimum | DEFault ]
Returned Parameters
<NR3>
Related Commands
POW:RANG
[SOURce:]POWer:RANGe
This command sets the power range of the electronic load module.
Command Syntax
[SOURce:]POWer:RANGe <NRf+>
Parameters
MINimum through MAX | MINimum | MAXimum | DEFault
Unit
W (power)
*RST Value
MAXimum (high range)
Examples
POW:RANG 15
SOUR:POW:RANGE MIN