SOURce Subsystem
Copyright © Itech Electronic Co., Ltd. 78
trigger.
TOGGle: The transient generator toggles between two levels upon receipt
of a trigger.
Command Syntax
[SOURce:]CURRent:TRANsient:MODE <mode>
Parameters
CONTinuous | PULSe | TOGGle
Returned Parameters
CONTinuous
Examples
CURR:TRAN:MODE TOGG
Query Syntax
[SOURce:]CURRent:TRANsient:MODE?
Returned Parameters
<CRD>
Related Commands
CURR:TRAN:ALEV TRAN
[SOURce:]CURRent:TRANsient:ALEVel
[SOURce:]CURRent:TRANsient:BLEVel
This command specifies the transient level of the input current. The transient
function switches between the level a and level b.
Command Syntax
[SOURce:]CURRent:TRANsient:ALEVel <NRf+>
[SOURce:]CURRent:TRANsient:BLEVel <NRf+>
Parameters
0 through MAX | MINimum | MAXimum | DEFault
Unit
A (amperes)