SOURce Subsystem
Copyright © Itech Electronic Co., Ltd. 67
Examples
INP:SYNC 1
Query Syntax
INPut:SYNCon[:STATe]?
Returned Parameters
0 | 1
Related Commands
INP:ALL
[SOURce:]INPut:SHORt
This command programs the specified electronic load module to the maximum
current that it can sink in the present operating range.
Command Syntax
[SOURce:]INPut:SHORt[:STATe] <bool>
Parameters
0 | 1 | OFF | ON
*RST Value
ON
Examples
INP:SHOR 1
Query Syntax
INPut:SHORt:STATe?
Returned Parameters
0 | 1
Related Commands
INP