Function and Features
 
  Copyright © ITECH Electronic Co., Ltd.  48 
NOTE 
In the following editing procedures, “Y” indicates selected status. To cancel selected status, 
press numeric key of corresponding step again. 
Operation steps 
1.  Press [Shift] + 2 (Program). 
PROGRAM 
Run    Recall    Edit 
2.  Operate Left/Right key and move to Edit. Press [Enter] key to enter editing 
test files. 
EDIT    PROGRAM 
Active Sequence=0987654321 
3.  Press numeric key to select required testing steps. The Active Sequence 
=09876543YY indicates that 1/2 steps have been selected. Press [Enter] 
key for confirmation. 
EDIT    PROGRAM 
Active Sequence=09876543YY 
4.  Select whether pause is necessary for these two steps. If step 2 is to be 
paused, press 2 key. If not, directly press [Enter] key for confirmation. 
EDIT    PROGRAM 
Pause Sequence=□□□□□□□□Y1 
5.  Select whether short-circuit test is necessary for these two steps. If step 1 
is to be tested, press 1 key. If not, directly press [Enter] key for 
confirmation. 
EDIT    PROGRAM 
Short    Sequence=□□□□□□□□2Y 
6.  Set loading time of step 1. If 2S is required, directly press 2 key on the 
board. Press [Enter] key for confirmation. 
EDIT  PROGRAM 
SEQ01 On Time=2S 
7.  Set unloading time of step 1. If 2S is required, directly press 2 key. Press 
[Enter] key for confirmation. 
EDIT  PROGRAM 
SEQ01 Off Time=2S 
8.  Set test delay time of step 1. If 1S is required, directly press 1 key. Press 
[Enter] key for confirmation. Tpf is delay time before measurement. 
EDIT    PROGRAM 
SEQ01 P/F Delay Time=1S 
9.  Set loading time of step 2. If 2S is required, directly press 2 key on the 
board. Press [Enter] key. 
EDIT  PROGRAM 
SEQ02 On Time=2S 
10.  Set unloading time of step 2. If 2S is required, directly press 2 key. Press 
[Enter] key. 
EDIT  PROGRAM 
SEQ02 Off Time=2S