Function and Features
Copyright © ITECH Electronic Co., Ltd. 48
NOTE
In the following editing procedures, “Y” indicates selected status. To cancel selected status,
press numeric key of corresponding step again.
Operation steps
1. Press [Shift] + 2 (Program).
PROGRAM
Run Recall Edit
2. Operate Left/Right key and move to Edit. Press [Enter] key to enter editing
test files.
EDIT PROGRAM
Active Sequence=0987654321
3. Press numeric key to select required testing steps. The Active Sequence
=09876543YY indicates that 1/2 steps have been selected. Press [Enter]
key for confirmation.
EDIT PROGRAM
Active Sequence=09876543YY
4. Select whether pause is necessary for these two steps. If step 2 is to be
paused, press 2 key. If not, directly press [Enter] key for confirmation.
EDIT PROGRAM
Pause Sequence=□□□□□□□□Y1
5. Select whether short-circuit test is necessary for these two steps. If step 1
is to be tested, press 1 key. If not, directly press [Enter] key for
confirmation.
EDIT PROGRAM
Short Sequence=□□□□□□□□2Y
6. Set loading time of step 1. If 2S is required, directly press 2 key on the
board. Press [Enter] key for confirmation.
EDIT PROGRAM
SEQ01 On Time=2S
7. Set unloading time of step 1. If 2S is required, directly press 2 key. Press
[Enter] key for confirmation.
EDIT PROGRAM
SEQ01 Off Time=2S
8. Set test delay time of step 1. If 1S is required, directly press 1 key. Press
[Enter] key for confirmation. Tpf is delay time before measurement.
EDIT PROGRAM
SEQ01 P/F Delay Time=1S
9. Set loading time of step 2. If 2S is required, directly press 2 key on the
board. Press [Enter] key.
EDIT PROGRAM
SEQ02 On Time=2S
10. Set unloading time of step 2. If 2S is required, directly press 2 key. Press
[Enter] key.
EDIT PROGRAM
SEQ02 Off Time=2S