Technical Specifications
Copyright © ITECH Electronic Co., Ltd. 60
Constant
power
Mode *3
Range
3.6KW 5KW
Resolution
100mW 100mW
Accuracy
0.2%+0.2%FS 0.2%+0.2%FS
Dynamic mode
CC mode
T1&T2
20uS~3600S /Res:1uS
Accuracy
5uS±100ppm
Ascending/descending
slope *4
0.001~0.1A/uS 0.01~1A/uS 0.001~0.1A/uS 0.01~1A/uS
Minimum rise time *5
80uS 100 uS
Measuring range
Read-back
voltage
Range
0~50V 0~500V 0~50V 0~500V
Resolution
1 mV 10 mV 1 mV 10 mV
Accuracy
±(0.025%+0.025%FS)
Read-back
current
Range
0~12A 0~120A 0~15A 0~150A
Resolution
1mA 10mA 1mA 10mA
Accuracy
±(0.05%+0.05%FS)
Read-back
power
Range
3.6KW 5KW
Resolution
100mW 100W
Accuracy
±(0.2%+0.2%FS)
Protection range
Overpower protection
3650W 5050W
Overcurrent protection
13.2A 132A 16.5A 165A
Overvoltage protection
530V 530V
Overtemperature
protection
85 85
Specification
Short circuit
Current (CC)
13.2A 132A 16.5A 165A
Voltage (CV)
0V
Resistance
(CR)
25mΩ 20mΩ
Input
terminal
impedance
1MΩ
Dimension
W439*H266*D590mm
Model IT8817C IT8818C
Rated value
( 0-40 °C)
Input voltage
0~120V 0~120V
Input current
0~600A 0~600A 0~72A 0~720A
Input power
4500W 6KW
Min. operating
voltage
0.18V/60A 1.8V/600A 0.18V/72A 1.8V/720A
Constant
Range
0.1~18V 0.1~120V 0.1~18V 0.1~120V

Table of Contents

Other manuals for ITech IT8800 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT8800 Series and is the answer not in the manual?

ITech IT8800 Series Specifications

General IconGeneral
BrandITech
ModelIT8800 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals