19
Controlling Lights with Sensors
Your security system can be programmed to turn on a
selected light or lights when sensors are activated. Each
time the chosen sensor is activated, the attached light(s)
will turn on for 5 minutes. When 5 minutes has passed
since the last activation, the light(s) will turn off. For exam-
ple, if you want house lights to turn on when you open
the front door, simply attach the desired lights to the front
door sensor.
Note: If a light is attached to a sensor and a schedule,
the light will only turn on and off within the
scheduled start and stop times.
To attach lights to sensors:
1. At an alphanumeric or fixed display touchpad,
enter the programming menus by pressing
9
+ System or Partition Master
CODE
.
2. Press
080
. The touchpad displays “LIGHT n TO
Sn x” or “LT n SN x,” (where n is the light number
and x is the sensor number).
3. Press
A
or
B
until the light number (1–9) you
would like to activate appears.
4. Enter the sensor number (1–76) you wish to acti-
vate the light and press
ƒ
.
5. Press
B
to assign another light to a sensor or press
+
00
+
ƒ
to exit the programming
menus.
To detach lights from sensors:
1. At an alphanumeric or fixed display touchpad,
enter the programming menus by pressing
9
+ System or Partition Master
CODE
.
2. Press
B
until the touchpad displays
ATTACH LIGHTS TO SENSORS” or “LITE TO SN”
then press
ƒ
.
3. The touchpad displaysLIGHT n TO Sn x orLT n
SN x,” (where n is the light number and x is the
sensor number).
4. Press
A
or
B
until the light number (1–9) you
would like to deactivate appears.
5. Enter the sensor number as 0 (no sensor) and
press
ƒ
.
6. Press
+
00
+
ƒ
to exit the programming
menus.
Installer Programmable Lighting
If you would like specific lights to turn on during Entry and
Exit Delay times, or if you would like a light to flash to indi-
cate successful arming and disarming, contact your
installer.
S
ECTION
13:
C
ONTROLLING
O
UTPUTS
BY
T
IME
S
CHEDULE
Outputs may be used to control devices in your home
such as automatic window blinds. Outputs that your
installer has enabled, can be turned on or off according to
time schedules. If you need assistance setting up a time
schedule that fits your needs, see “Creating Time Sched-
ules” on page 17.
To schedule outputs:
1. At an alphanumeric or fixed display touchpad,
enter the programming menus by pressing
9
+ System or Partition Master
CODE
.
2. Press
065
+
ƒ
.
3. The touchpad displays “OUTPUTS.” Press
ƒ
.
4. Press
B
until the touchpad displays the output
number you would like to schedule. Refer to
Appendix A: User Sheets” on page 38 to deter-
mine which output is associated with which output
number.
5. Press
ƒ
. The touchpad displays the first available
time schedule.
6. Enter
2
+
ƒ
to assign the time schedule (“ON”) for
this output.
1
+
ƒ
to make the time schedule inactive for
this output.
7. Press
B
to go to the next time schedule, if
needed, and turn the schedule on or off for this
output.
8. When you’ve finished attaching the desired time
schedules, press
+
00
+
ƒ
to exit the
programming menus.