EasyManua.ls Logo

ITI Concord - SECTION 9: USING THE ENERGY SAVER FEATURE; Energy Saver Example; Setting the Energy Saver High and Low Temperature Settings; Turning Energy Saver On and Off

Default Icon
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
S
ECTION
9:
U
SING
THE
E
NERGY
S
AVER
F
EATURE
Use the Energy Saver feature to keep your house within a
user-designated temperature range. These high and low
temperature points that you set override your normal
heating and air conditioning temperature settings. Doing
so allows you to use more energy-efficient settings when
away from home.
Energy Saver Example
It works like this:
At your touchpad, you set a high temperature point (to
trigger the air conditioner) and a low temperature point
(to trigger the furnace). This needs to be done only
once, but can be changed easily if necessary.
Let’s say that you usually keep the temperature in your
home at 68°F, but since no one will be there during the
day, you turn the Energy Saver feature on. If you’ve set
the low temperature point to 55°F, the furnace will
keep the house heated to 55°.
You’re about to return home and would like the house
to be heated to its normal 68°F when you arrive. If you
have a Phone Interface and Voice Module installed,
you can simply call home and turn the Energy Saver fea-
ture off, giving control back to the furnace thermostat
(68°).
Control your air conditioning temperatures in the same
manner.
In addition to controlling temperature, the Energy Saver
feature notifies the central monitoring station if your heat-
ing or air conditioning unit fails—before pipes freeze or
pets are harmed by extreme heat or cold.
Setting the Energy Saver High and
Low Temperature Settings
Initially, you must set the energy saver to the desired high
and low temperatures. This is done only once, unless you
want to change temperature settings.
The high and low settings you enter do not control heat-
ing and cooling systems, but determine the point at which
the furnace or air conditioner is activated.
Temperature settings can range from 45° to 90°
Fahrenheit.
To set the Energy Saver temperature range from a
touchpad:
1. Enter the programming menus by pressing
9
+ System or Partition Master
CODE
.
2. Press
070
.
3. Enter the lowest allowable temperature (45–89°F)
before the furnace turns on, and press
ƒ
.
4. Press
B
. Enter the highest allowable temperature
(46–90°F) before the air conditioner turns on, then
press
ƒ
.
5. Press
+
00
+
ƒ
to exit the programming
menus.
Turning Energy Saver On and Off
To override your normal heating or air conditioning set-
tings, turn the Energy Saver feature on. When you are
ready to return to your normal temperature control set-
tings, turn Energy Saver off.
To turn Energy Saver on/off from any touchpad:
1. Press
7
+
2
. Alphanumeric touchpads display,
“ENERGY SAVER IS ON,” for example.
S
ECTION
10:
N
OTIFICATION
BY
P
AGER
Your system can notify up to five different pager phone
numbers to report system events. The installer can pro-
gram any pager to receive pages for one or more of the
following groups:
High
Setpoint
90°
Low
S
etpoint
45°
If room tem perature
re a c h e s lo w se tp o in t,
fu rn a c e tu rn s o n .
If room tem perature
re a c h e s h ig h se tp o in t,
a ir c o n d itio n e r tu rn s o n .
High Level Reports Low Level Reports
Sensor
Alarms
Freeze
Alarms
Bypass
Sensors
AC Power
Failure
Tamper Freeze
Troubles
Low
Battery
CPU Low
Battery
Restorals No Activity
Alarm
Supervisory Auto Phone
Test
Phone Tests Fire Panic Trouble CPU Back
in Service
Receiver
Failure
Police Panic Phone Test Phone
Failure
Receiver
Jam
Auxiliary
Panic
Event Buffer
Full
Touchpad
Low
Battery
Touchpad
Tamp er
Bus
Failures
Opening and Closing Reports
Latchkey Reports
Notify by Exception Reports

Table of Contents