iTriangle Infotech Pvt Ltd
Interface 31 of 43
Note: Engineering Documents are Highly Confidential
7.6.1.7 SET_ODOM
This command is used to set the odometer value in the device so that the device starts accumulating
the distance from set value. The maximum value after which the odometer will get rollover
99999000.
Syntax:
set$<Serial Number/IMEI>@<Password>#SET_ODOM:<Distance in meter>*
<Distance in meters >: Odometer value in meters
Example:
set$140613238@aquila123#SET_ODOM:000000*
set$140613238@aquila123#SET_ODOM:5000*
Note: 5000 menace 5 KM
7.6.1.8 CFG_ANGLPOL
This command is used to enable and set the angle based acquisition and set the threshold heading
difference for generating an event packet.
Syntax:
set$<SerialNumber>@<Password>#CFG_ANGLPOL:<1=Enable/0=disable>,<Angle in degree (Angle
range: 30-330)>*
<1=enable>: Enable angle polling
<0= disable>: Disable angle polling
<Angle in degree>: Angle range: 30 - 330
Example: set$140613238@aquila123#CFG_ANGLPOL:1,45*
7.6.1.9 CFG_ANFILT
This command is used to add the IIR filter for Analog input value which is read. This feature will filter
out abrupt variations in the analog input.
Syntax:
set$<SerialNumber/IMEI>@<Password>#CFG_ANFILT:<1=Enable/0=Disable>*
Example:
set$140613238@aquila123#CFG_ANFILT:1*
7.6.1.10 CFG_COMPBF
This command is used to enable/disable the compress bit field in the packet which are sent to the
server. If this feature is enabled the all the 32-bit fields from 18
th
to 49
th
position will be compressed
to a decimal event flag. This will save the 50 bytes of data from the payload.
Syntax:
set$<Serial Number/IMEI>@<Password>#CFG_COMPBF:<1=Enable/0=Disable>*
Example:
set$140613238@aquila123#CFG_COMPBF:1*